Skip to content
(817) 589-7101

Comparison

EN 856 4SP vs EN 856 4SH

Both are European four-spiral hoses; 4SH is the heavier spec — at -12 it rates roughly 6,090 psi versus 4SP's 4,050 psi. Laylines decide: replace 4SH with 4SH. Where a circuit sits within 4SP's rating, the lighter hose routes more easily and costs less.

Side by side

The decision table.

4SP vs 4SH Spiral Hose
EN 856 4SPEN 856 4SH
-12 rating4,050 psi6,090 psi
-16 rating3,625 psi5,510 psi
-20 rating3,190 psi5,075 psi
Bend radiusSmallerLarger
Weight/costLowerHigher

Choose EN 856 4SP when…

  • Circuits within 4SP ratings on European equipment

Choose EN 856 4SH when…

  • Main circuits on big excavators, demolition and piling rigs
  • Anything the OEM plumbed with 4SH

What happens if you mix them

Substituting 4SP where 4SH was specified strips the safety factor from a 6,000 psi-class circuit. Read the layline of the failed hose — then match or exceed it.

4SP vs 4SH Spiral Hose — FAQs

The layline is worn off — how do you identify my spiral hose?

By OD, bore, ply count on the cut end, and the machine's circuit spec. When in doubt we build to the higher rating.

Still deciding?

Bring both fittings to the counter — or call (817) 589-7101 and read us the layline. We settle these in minutes, with the gauges out.

Get the right part quoted