Skip to content
(817) 589-7101

Comparison

SAE 100R1 vs SAE 100R2

R1 carries one wire braid, R2 carries two — and roughly twice the working pressure at every size. R1 belongs on returns and drains; R2 is the default pressure-line braid hose. The price difference is small; the rating difference isn't.

Side by side

The decision table.

SAE 100R1 vs 100R2 Hose
SAE 100R1SAE 100R2
Braids12
-8 rating2,325 psi4,000 psi
-12 rating1,825 psi3,125 psi
-16 rating1,300 psi2,400 psi
Typical dutyReturn/case drainPressure lines

Choose SAE 100R1 when…

  • Return lines, drains, low-pressure supply where budget matters

Choose SAE 100R2 when…

  • Any pressure line within its chart rating
  • When you'd rather stock one braid hose than two

What happens if you mix them

R1 on a pressure circuit is the classic parts-store fatality: it holds on day one and fails on the hot, hard day. Check circuit pressure against the size-specific chart, not the hose family name.

SAE 100R1 vs 100R2 Hose — FAQs

Can I just always buy R2?

For braid-hose duties, that's a defensible one-hose policy — R2 covers everything R1 does with margin. Suction still needs R4, and high-impulse mains still need spiral.

Still deciding?

Bring both fittings to the counter — or call (817) 589-7101 and read us the layline. We settle these in minutes, with the gauges out.

Get the right part quoted